BJKWJ - FAULT-FINDER DEVELOPER 1013

Product Identification

Product ID:FAULT-FINDER DEVELOPER 1013
MSDS Date:04/14/1986
FSC:6850
NIIN:00-160-8480
MSDS Number: BJKWJ

Responsible Party
CROWN INDUSTRIAL PRODUCTS CO., INC.
STATE LINE ROAD
HEBRON, IL 60034
US

Emergency Phone: 815-648-2424

Info Phone: 815-648-2424

Preparer: ROBERT E. BAYTON

Cage: 92381

Contractor
CROWN INDUSTRIAL PRODUCTS CO
350 HEBRON, IL 60034 US

Telephone: 815-648-2424

Cage: 92381

Ingredients

OCTYLPHENOXYPOLYETHOXYETHANOL

CAS: 9036-19-5

RTECS: MD0907600

Fraction By Weight: 1-10%


LIQUIFIED PETROLEUM GAS, SWEETENED (11-30%) THIS IS MIXTURE

CAS: 68476-86-8

Fraction By Weight: 11-30%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 1-10%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 11-30%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LIQUIFIED PETROLEUM GAS, SWEETENED (11-30%) THIS IS MIXTURE

CAS: 68476-86-8

Fraction By Weight: 11-30%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CAN CAUSE IRRITATION TO NOSE, THROAT,
RESPIRATORY TRACT, EYES, AND SKIN. PROLONGED EXPOSURE ABOVE OSHA
PERMISSIBLE EXPOSURE LIMITS MAY RESULT IN KIDNEY AND LIVER DAMAGE.
Explanation of Carcinogenicity:METHYLENE CHLORIDE IN THE PRODUCT MAY
NOT CAUSE ANY PROBLEM BUT IT IS SUSPECTED CARCINOGEN.
Effects of Overexposure:INHALATION: MAY BE IRRITATING TO NOSE, THROAT,
AND RESPIRATORY TRACT. HIGH CONCENTRATION MAY RESULT IN CNS
DEPRESSION. INGESTION: MAY RESULT IN VOMITING. LOW TOXICITY. EYES:
MAY CAUSE IRRITATION AND CORNEAL INJURY. SKIN: MAY CAUSE
IRRITATION , DEFATTING AND/OR DERMATITIS. SKIN ABSORPTION: LOW
TOXICITY.
Medical Cond Aggravated by Exposure:PREEXISTING EYE, SKIN AND
RESPIRATORY DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO THIS
PRODUCT. MAY INCREASE MYOCARDIAL IRRITABILITY. AVOID EPINEPHRINE OR
SIMILAR DRUGS IF AT ALL POSSIBLE.

First Aid

First Aid:INGESTION: DO NOT INDUCE VOMITING.IF VOMITING OCCURS
SPONTANEOUSLY, KEEP HEAD BELOW HIPS TO PREVENT ASPIRATION OF LIQUID
INTO THE LUNGS. CALL A DOCTOR. DO NOT GIVE EPINEPHRINE OR SIMILAR
DRUGS. INHALA TION: REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING
IS DIFFICULT. GIVE ARTIFICIAL RESPIRATION IF NOT BREATHING. EYES:
FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH SOAP AND
WATER.

Fire Fighting

Flash Point:N/R (AEROSOL CAN
Lower Limits:1.8
Upper Limits:9.5
Extinguishing Media:WATER FOG, DRY CHEMICAL, FOAM, CARBON DIOXIDE
Fire Fighting Procedures:COOL EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:AEROSOPL CANS WILL EXPLODE IN HEAT OF
FIRE. TREAT AS CYLINDER OF COMPRESSED GAS. FACE SHIELDS, HELMETS
AND SELF CONTAINED BREATHING APPARATUS IS RECOMMENDED.

Accidental Release

Spill Release Procedures:IF LIQUID SPILLS OUT, VENTILATE AREA. REMOVE
ALL SOURCES OF IGNITION. CLEAN UP WITH INERT MATERIALS. SEGREGATE
AND REMOVE THE LEAKING AEROSOL CANS.

Handling

Handling and Storage Precautions:DO NOT STORE IN DIRECT SUNLIGHT OR
WHERE TEMPERATURE EXCEED 120F. AVOID SPLASH FILLING, OPEN FLAME,
SPARKS. USE IN WELL-VENTILATED AREA.
Other Precautions:DO NOT SPRAY ON FLAMES, HOT SURFACES. AVOID
INHALATION OF VAPORS. AVOID PHYSICAL DAMAGE TO THE CONTAINERS.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR TO PREVENT
OVER-EXPOSURE IN ACCORDANCE WITH 29CFR1910.134
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:POLYETHYLENE OR NEOPRENE
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NONE
Work Hygienic Practices:AIR DRY CONTAMINATED CLOTHING AND LAUNDER
BEFORE RE-USE.
Supplemental Safety and Health
FAULT FINDER DEVELOPER 1013 WASGROUP 1A UNDER QPL-25135-13. NOW UNDER
QPL-25135-15 IS TYPE II, FORM D DEVELOPER FOR MIL-I-25135, REVISION
E. LIQUIFIED PETROLEUM GAS SWEETENED IS PROPELLANT.

Chemical Properties

HCC:V3
Vapor Pres:40-45 PSIG
Vapor Density:>1
Spec Gravity:>1
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:SLIGHT
Appearance and Odor:WHITE LIQUID, ETHEREAL ODOR BEFORE FILLING IN
AEROSOL CANS.
Percent Volatiles by Volume:90.0

Stability

Stability Indicator/Materials to Avoid:YES
CAUSTIC ALKALI OR STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:OPEN FLAMES OR SPARK SOURCES
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY PRODUCE
HYDROGEN CHLORIDE AND SMALL AMOUNTS OF PHOSGENE AND CHLORINE.

Disposal

Waste Disposal Methods:AEROSOL CONTAINER: DO NOT PUNCTURE OR
INCINERATE. EMPTY CONTAINERS MAY BE DISPOSED OF THROUGH NORMAL
CHANNELS. FULL OR PARTIALLY FILLED CONTAINERS ARE CONSIDERED
HAZARDOUS WASTE. COMPLY WITH ALL FEDER AL, STATE, LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.